CM/DM 6060F/6510F Chairman/Delegate Units
The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of
CM/DM 60x0 pr output
10 m 1 m 39 m 30
30 m 1 m 56 m 27
50 m 1 m 73 m 24
100 m 1 m 115 m 16
150 m 1 m 160 m 11
10 m 2 m 64 m 28
30 m 2 m 78 m 25
50 m 2 m 94 m 23
100 m 2 m 130 m 16
150 m 2 m 170 m 11
CM/DM 6560F Chairman/Delegate Units
Length of Feeding Cable
Type CAT5 AWG24
Length of inter-connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of CM/DM
60x0 pr output
10 m 1 m 35 m 27
30 m 1 m 53 m 24
50 m 1 m 70 m 21
100 m 1 m 113 m 14
150 m 1 m 159 m 10
10 m 2 m 58 m 25
30 m 2 m 72 m 22
50 m 2 m 88 m 20
100 m 2 m 126 m 14
150 m 2 m 166 m 9